BITUTHENE 3000: Thin waterproof membrane for roof and floor, polyethylene original bitumen / rubber self adhesive and available high-quality fixed for tunnels and structures.
![]() |
![]() |
![]() |
|
This is photos, that Quocthang Co construct Bituthene 3000 |
||
- Cross-fiber membrane sheets - offers resilient durable, resistant to tears force, penetration and impact.
- Only layer – Simple, reliable, low labor during the construction.
- Cold applied - no hot, fire.
- Self-adhesive - the continuity is guaranteed in the joints, rubber formula / Bitumen allows filling small openings.
- Manufacturer control thickness of product - not the situation that heterogeneity occurs during construction.
- Resistant to chemicals - effective surface protection against harsh environmental conditions and attack the ozone.
II- APPICATIONS:
Bituthene 3000 is a flexible membrane fixed available, self adhesion, high quality for use as floor roof terrace and garden terrace. Products formed by a thin layer of HDPE and a self-adhesive Bitumen rubber.
II- APPICATIONS:
Bituthene 3000 is a flexible membrane fixed available, self adhesion, high quality for use as floor roof terrace and garden terrace. Products formed by a thin layer of HDPE and a self-adhesive Bitumen rubber.
III- SPECIFICATIONS:
|
Features |
Typical Value |
Test Method |
|
Coulors |
Dark brown / black |
|
|
Tensile strength (only for sheet film) |
40.000kN/m² |
ASTM D882 |
|
Membrane durability |
5,10N/mm |
ASTM D412 |
|
Elongation of film (until the break of rubberised bitumen) |
300% |
ASTM D412 |
|
Clamping force at joint @ 23 ° C |
683N/m |
ASTM D1876 |
|
Bending experiments @ -32 ° C |
No effect after 100 times |
ASTM C836-89a |
|
Puncture resistance |
250N |
ASTM E154-88 |
|
Ability of water column pressure |
60m |
ASTM D5385 |
|
Bearing capacity impact |
12kg-cm |
ASTM G14 |
|
Bearing capacity torn |
32N/mm |
ASTM D624 |
|
Conductivity from |
2ng/m².s.Pa |
ASTM E96 [12] |
- The typical test values can represent the average values from samples tested. Test methods have been recorded can be adjusted.
IV- CONSTRUCTIONS:
- Resistant to chemicals - effective surface protection against harsh environmental conditions and attack the ozone.
- Need to apply measures to ensure that no surface ice, frost or condensation. Roof surface should be dry, clean off the protruding sharp objects and plug the holes filled with high strength mortar. The construction should be done in temperatures from 4 ° C to 55 ° C. The horizontal and vertical surface must be flat, even, dry and no screws. Horizontal and vertical surfaces covered with a layer of Primer : Primer B1 or B2 by brush or roller at a rate 6-8 (8-10) m² per liter depending on the status of surface pitting, and dried completely before use Bituthene 3000.
- Bituthene 3000 posted by slicing the protective paper and pasted on construction adhesive to the surface to ensure good initial adhesion. The scroll at the side must be aligned to each other and overlap at least 50mm at the edge and bottom edge, and the overlap should be pressed tightly rolled joints with lots of fruit Bituthene (Bituthene Lap Roller) to ensure the link adhesion and integrity between the layers. Compliance and implementation of construction inspection to prevent damage and accidents during construction. This has been put into use after construction, Bituthene 3000 should be protected from weather and physical damage by using protective cover or rolling on the surface mortar. Any holes or damaged areas should be cleaned and patched with a piece stuck Bituthene 3000 are more extensive damage of at least 50mm.
- The open vertical plane should be protected from the harmful effects of UV radiation using sheet protection.